id:= 012106
Blank raster with purity error
This fault is actually field collapse which is shifted off screen with beam reflected from bowl of crt, check output ic also L1501 and L1503 on 15+, 15- rail


id:= 014073
Front led flashing 13 times, field problems
Replaced the field ic TDA8179 with a STV9379, also replaced the 0.47ohm resistor at pin 7 of the flyback transformer (in the negative 15 volt supply to the output chip) which was o/c


id:= 014074
Int picture blanking leaving osd and dark green raster
Adjust the auto green cut off and adjust grey scale using electronic screwdriver settings


id:= 014075
No colour
Replaced decoder chip IC301 (TDA9145), the chroma delay line (TDA4660) and Xtals X301/2


id:= 012102
No colour with video playback especially with 2nd generation copies
Change IC301 from TDA9145/N1 or TDA9145N2B to TDA9145N3C (Pt. no. 8-759-343-40), replace L307 (4.7uH) with a link wire and replace R316 (33K) with a 100K (Pt no. 1-216-097-00)


id:= 014076
No sound / picture, 1 l.e.d only lit
Check for dry joints on the field output chip also check other relevant areas for dry joints as a precaution


id:= 017022
No text. Picture tearing in a pulsing time constance
Eprom corrupted due to dry joints causing spikes. Initialise
(Ian Hayward - HTV. Services)


id:= 014077
Picture intermittently blanks out then shuts down and restarts
Loss of field output due to dry joints on the field output chip (next to l.o.p.t by back panel)


id:= 012104
Random spikes and distortion, high sound on left speaker
Add a 3.3Kohms resistor and a 0.015uF capacitor in parallel with C201


id:= 014078
Trips 13 times (indicates field fault)
This was due to the STB9379 field chip (can use TDA8179S ??)


id:= 014079
Vertical ripple and `staining` effect
Check double diode D613 in the p.s.u for leakage


id:= 014080
Will not come out of standby / int
Check the field output chip TDA8179


Do you have repair tips / fault reports for this model not listed above? Please send them in and help others who may be stuck !!
Click on the button at the top of this page - Many Thanks





Copyright © 2000 - 2003 - E.C.S (Technical Publishing)
Site Design & Layout © 2000
All Rights reserved

All Information is supplied as per our Site Terms.
Use of this site deems your acceptance of these terms.
Click links to view our Site Terms and Privacy Policy


Sony AE2 TV ( AE2 Chassis ) repair tips and faults search the forum TV Sony AE2 ( AE2 Chassis ) faulty repair remote TV AE2 ( AE2 Chassis ) fix faulty repair tips TV ( AE2 Chassis ) Sony AE2 faults repairs tips monitor faults free newsletter repair items for sale repair parts spares circuits wanted repair help Sony AE2 TV ( AE2 Chassis )
.